sheer and bond tests (3)


Aitahdr.gif (5343 bytes)

March 7, 1985

ICS/Penetron International Ltd.
45 Research Way
Suite 203
East Setauket, NY 11733

Re: Information of Client

A. SHEAR TESTS
1. Effect of Penetron when new concrete is placed against existing concrete.

AGE IN DAYS:  LOAD (lb.)
 14   28
Reference      3113   4086
Penetron Slurry         3343   4104
Penetron Powder     2335   2868

B. BOND TESTS
1. Effect of Penetron on Bond of Reinforcement Steel Embedded in Concrete.

AGE IN DAYS:  LOAD (lb.)
 14   28
Reference      * 7280
Penetron Slurry         *  7495

*-In both Reference and Penetron Treated specimens, the reinforcement steel yielded with the steel still firmly bonded to the concrete.

2. Bonding qualities of Penetron on hardened concrete to hardened concrete.

AGE IN DAYS:  LOAD (lb.)
 14   28
Penetron Slurry         340    540

AitaSIG.gif (3547 bytes)