Foundation walls, retaining walls, pit walls, and slabs
Area: Exterior or interior application against or with the pressure of water.
Consumption for Waterproofing: Brush application: 0.8kg./sq.m 5 parts PENETRON to 2 parts water (5:2)
1.1kg./sq.m 3 parts PENETRON to 1 part water

Spray application: 5 parts PENETRON to (2.75 to 3.25) parts water.
Varies with climate an spray equipment.
Consumption for Damproofina: Note: When working against the water pressure, construction joints, cracks, junction wall/slab should be cut out as square-shaped as possible (see drawings).
Click to see diagram


Foundation slabs, Parking slabs, etc
Waterproofing: For foundation slabs, parking slabs, cast-in-place.
Consumption: Penetron Plus (powder) 1 lb. (0.45 kg)/sq, yd. OR 2.5 lbs. (1.13 kg) of Penetron (powder) trowel applied.

Penetron is applied in powder consistency by sieve or broadcast at specified quantities when the cast concrete is still in its plastic state.
Finishing: Penetron treated surfaces are finished by float or power trowel, as specified, following normal concrete placement procedure.
Curing: Follow the concrete specification in question. Do not apply water sprinklers until initial set of concrete.

Apply curing agents per concrete specifications.


Diagram for walls, retaining walls, pit walls, and slabs
Click on more info for video and image details